Material ID: 6ES7142-6BR00-0BB0
SIMATIC ET 200eco PN
The SIMATIC ET 200eco PN is a compact block I/O system with a PROFINET connection. It offers a high degree of protection with IP65/67 rating, making it a space-saving and future-oriented solution. The system sets new market standards and requires minimal installation effort.
Technical Features:
Commercial Benefits:
The SIMATIC ET 200eco PN offers several commercial benefits:
With the SIMATIC ET 200eco PN, you have a future-oriented and innovative complete solution that offers both advanced technical features and commercial benefits.
- DQ 8x 24 V DC/2A: 8 digital outputs with 24 V DC and 2A current
- M12-L: M12-L coded power connectors for simplified power supply concept
- 8x M12: 8 M12 connectors for single and double assignment
- Source Output: PNP switching to P potential
- Substitute Value Output: Provides substitute value output
- Channel Diagnostics: Detects wire break and short-circuit at the output
- Shared Device: Can be shared with 2 controllers
- 0.25 ms Isochronous Mode: Supports 0.25 ms isochronous mode
- Prioritized Startup: Supports prioritized startup
- MSO, MRP, S2 Redundancy: Supports MSO, MRP, and S2 redundancy
- I&M0…3: Supports I&M0…3
- Multi-Fieldbus: Supports multi-fieldbus
- PN IO, Ethernet IP, Modbus TCP: Supports PN IO, Ethernet IP, and Modbus TCP
- Degree of Protection: IP67 / IP69K
- Flexible Configuration: The system can be flexibly configured thanks to the integrated 2-port switches.
- Easy Installation: The block I/Os can be quickly and flexibly installed in any position, directly on-site.
- Rugged Design: The die-cast zinc housing provides ideal protection in challenging ambient conditions and allows for operation in temperatures ranging from -40 °C to +60 °C.
- Resistance to Environmental Factors: The system is highly resistant to vibration, dust, oil, and humidity.
- Extended Cable Lengths: The M12-L coded power connectors enable higher current-carrying capacity, allowing for substantially longer cable lengths in the field without additional power supply cables.
- Future-Oriented Solution: Siemens guarantees future-oriented and innovative solutions that help businesses move into new segments with key technologies.
- Expanded Product Range: In addition to digital and analog input and output modules, the range of products includes IO-Link master and a fail-safe module for connecting sensors and actuators up to SIL 3/PLe.
- Fail-Safe Operation: The outputs of the standard modules can be practically disconnected in a fail-safe manner up to SIL 2.
Additional Information
Support | Technical Data | Manuals / Links |
| FEATURE | VALUE |
| Supporting protocol for Foundation Fieldbus | false |
| Number of HW-interfaces RS-485 | 0 |
| Supporting protocol for PROFIBUS | false |
| Supporting protocol for LON | false |
| Supporting protocol for INTERBUS | false |
| Supporting protocol for KNX | false |
| Width | 45 mm |
| Fieldbus connection over separate bus coupler possible | false |
| Supporting protocol for AS-Interface Safety at Work | false |
| Number of digital outputs | 8 |
| Supporting protocol for other bus systems | false |
| Supporting protocol for CAN | false |
| Supporting protocol for TCP/IP | true |
| Front built-in possible | true |
| Permitted voltage at output | 28.8 V |
| Supporting protocol for SERCOS | false |
| Radio standard GPRS | false |
| Number of HW-interfaces RS-232 | 0 |
| Output current | 2 A |
| Number of digital inputs | 0 |
| Number of HW-interfaces serial TTY | 0 |
| Supporting protocol for INTERBUS-Safety | false |
| Voltage type (supply voltage) | DC |
| Number of HW-interfaces wireless | 0 |
| Number of HW-interfaces parallel | 0 |
| Time delay at signal change | 0.05 ms |
| Supporting protocol for SUCONET | false |
| Supporting protocol for DeviceNet Safety | false |
| Supply voltage DC | 28.8 V |
| Supporting protocol for PROFINET CBA | false |
| Rail mounting possible | true |
| Digital outputs configurable | true |
| Type of output voltage | DC |
| System accessory | true |
| Permitted voltage at output | 0 V |
| Rack-assembly possible | false |
| Supporting protocol for ASI | false |
| Supporting protocol for Modbus | true |
| Appendant operation agent (Ex ib) | false |
| Radio standard UMTS | false |
| Number of HW-interfaces RS-422 | 0 |
| Supporting protocol for PROFINET IO | true |
| Radio standard Bluetooth | false |
| Number of HW-interfaces other | 0 |
| Supporting protocol for Data-Highway | false |
| Time delay at signal change | 0.1 ms |
| Supporting protocol for DeviceNet | false |
| Number of HW-interfaces industrial Ethernet | 0 |
| Supply voltage DC | 20.4 V |
| Supporting protocol for PROFIsafe | false |
| Wall mounting/direct mounting | true |
| Depth | 48 mm |
| Supporting protocol for SafetyBUS p | false |
| Suitable for safety functions | false |
| Short-circuit protection, outputs available | true |
| Number of interfaces PROFINET | 1 |
| Appendant operation agent (Ex ia) | false |
| Supporting protocol for EtherNet/IP | true |
| Radio standard GSM | false |
| Number of HW-interfaces USB | 0 |
| Height | 200 mm |
| IO link master | false |
| With optical interface | false |
| Radio standard WLAN 802.11 | false |